Walking in the streets, people can see LED display everywhere. The installation of LED large screens also has a lot of tricks, both aesthetic and cost savings. So, in the end how to choose the installation of LED display it? In general, outdoor LED display screens are installed in columns, roofs, and mosaics, while indoor LED displays mainly include wall-mounted installation, hoisting, and floor-standing installations. Here is a detailed description of the LED display manufacturers' installation methods:
LED display common installation methods are mainly the following six kinds:
1. Mosaic installation: Indoor, suitable for small indoor screens. Due to the small installation space, in order not to occupy space, the same size area is dug on the wall according to the size of the screen body, and the LED display screen is embedded in the wall. The wall is required to be a solid wall. Using pre-maintenance means higher costs. In outdoor installation, the inlay structure is suitable for the display items already included in the building planning and design. The space for the display screen is reserved in advance during the construction of the civil project. In actual installation, only the display steel structure is required to display the screen. Inlaid in the building wall, leaving enough maintenance space on the back.
2, wall-mounted installation: more suitable for indoor LED display installation, smaller area (10 square meters or less), wall requirements are solid wall, hollow brick or simple partition wall are not suitable for this installation.
3, hanging installation: more suitable for station LED electronic display, airport LED electronic display and other large venues to play a signage role. It requires a small screen area. (Below 10 square meters) Requirements There must be a suitable installation location, such as a beam or lintel at the top, and the screen body should normally be added with a back cover. Ordinary mounting is suitable for single-casing display screens with a total screen weight of less than 50kg. It can be directly hung on the load-bearing wall. No maintenance space is required. The display cabinet adopts a frontal maintenance design. The display screen is opened from the bottom during maintenance. You can. The rack mount is suitable for general outdoor displays. Taking into account the difficulty of screen maintenance, steel structures are used between the screen body and the wall to reserve 800mm of maintenance space. Space is equipped with maintenance facilities such as horse trails and ladders. And install auxiliary equipment such as power distribution cabinets, air conditioners, axial fans, and lighting.
4, column type installation: used for outdoor advertising LED electronic display installation, open vision, surrounded by relatively empty places, such as squares, parking lots and so on. According to the size of the screen area can be divided into single column and double column installation. The column is suitable for the installation of LED displays on open spaces and the outdoor screen is mounted on the columns. In addition to the column-type steel structure to produce the screen, but also need to make concrete or steel columns, mainly considering the basic geological conditions.
5. Roof-mounted installation: It is mainly applicable to outdoor advertising LED electronic display screens, and the installation site is mainly the roof of the building. With the increase of the building height, the level of wind protection to be considered also increases.
6. Seat-mounted structure is to use a concrete structure on the ground to install a wall that is sufficient to support the entire LED display screen. The steel structure is installed on the wall to install the display screen. The steel structure reserves 800mm of maintenance space, and the relevant equipment and maintenance facilities are placed. .
Installation of outdoor LED display installation considerations
The outdoor LED display area is large, and the design of its steel structure must take into consideration many factors such as foundation, wind load, magnitude, waterproof, dustproof, ambient temperature, and lightning protection. In the steel structure, auxiliary equipment such as power distribution cabinets, air conditioners, axial fans, and lighting shall be placed, as well as maintenance facilities such as horse trails and ladders. The entire outdoor screen structure should meet the protection level below IP65. In general, the following considerations when installing outdoor LED display installations include:
(1) The display is installed outdoors, often exposed to the sun, rain, sun, and the working environment is harsh. If the electronic device is wetted or severely dampened, it may cause a short circuit or even a fire, causing a malfunction or even a fire, resulting in damage.
(2) The display may be subject to strong magnetic shocks caused by lightning.
(3) The temperature of the environment changes greatly. The display screen itself generates a certain amount of heat. If the ambient temperature is too high and the heat dissipation is poor, the integrated circuit may not work properly or may even be burned, thereby rendering the display system unable to operate normally.
(4) The audience is wide, the line-of-sight distance is long and the field of vision is wide; the ambient light changes greatly, and in particular it may be exposed to direct sunlight.
For the above special requirements, outdoor display installation must be:
(1) The screen body, and the joint between the screen body and the building must be strictly waterproof and leakproof; the screen body must have good drainage measures and can be smoothly discharged once the water accumulation occurs.
(2) Install lightning protection devices on display screens and buildings. The main body of the display screen and the casing are well grounded, and the grounding resistance is less than 3 ohms, so that large currents caused by lightning discharge in time.
(3) Install the ventilation equipment to reduce the temperature, so that the internal temperature of the screen is between -10 °C ~ 40 °C. An axial fan is installed behind the screen body to discharge heat.
(4) Select industrial-grade integrated circuit chips whose operating temperature is between -40°C and 80°C to prevent the display from starting when the temperature is too low in winter.
(5) It has the characteristics of “five protections†against direct sunlight, dust, water, high temperature, and short circuits.
2 Post Car Lift
2 post car lift is a new generation of product with new design. The whole is made of high-strength aluminum profiles. Due to the high strength of the profiles, the deflection and swing of the elevator are extremely small. Double mast column structure is adopted, with large load capacity, large platform area, excellent stability, flexible operation and convenient implementation. Its lightweight appearance can give full play to the highest lifting capacity in a small space. The elevator is widely used in factories, hotels, buildings, shopping malls, stations, airports, stadiums, etc. It can be used for installation and maintenance of power lines, lighting appliances, overhead pipelines, and high-altitude cleaning.
The free lifting feature of two post car lift has been widely used in municipal maintenance, cargo transportation of wharf and logistics center, building decoration, etc. the car chassis, battery car chassis, etc. can walk freely, and the working height and space are also changed. It has the advantages of light weight, self walking, electric starting, self supporting, simple operation, large working surface, and 360 degree free rotation, especially the ability to cross obstacles for high-altitude operation.
The lifting height of two post car lift varies from 4m to 18m. The load of this series of products is divided into 0.1 to 0.8 tons, and can also be customized according to the requirements of users. The maximum load can reach 10 tons. The equipment that can be used for vertical transportation in logistics systems such as factories or automatic warehouses. The elevators are often equipped with various plane transportation equipment as connecting devices for transportation lines of different heights.